Loading...
C2018-17 Bid TabsC2018-17 Metropolitan Area Network Fiber Installation (#5683743) Owner: City of Janesville, WI Solicitor: City of Janesville, WI 05/02/2018 02:00 PM CDT Section Title BASE BID - A **Full description as stated in contract, truncated in vBid** ALTERNATE BID 1 - COUNTY JOB CENTER **Full description as stated in contract, truncated in vBid** ALTERNATE BID 2 - UW ROCK **Full description as stated in contract, truncated in vBid** Base Bid Total: Line Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 Item Code 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R 25R 26R 27R 28R 29R 30R 31R 32R 33R 34R 35R 36R 37R 38R 39R 40R 41R 42R 43R 44R 45R 46R 47R 48R 49R 50R 51R 52R 53R 54R 55R 56R 57R 58R 59R 60R 61R 62R 63R 64R 65R 66R 67R 68R 69R 70R 71R 72R 73R Item Description Provide and Directionl Bore 2" SDR 11 Duct Part#:Carlon A13C6N1JNNE (2 inch) or equivelant Provide and "Rock" Directionl Bore 2" SDR 11 Duct under Rock River for Waste Water Treatment Connection Part#:Carlon A13C6N1JNNE (2 inch) or equivelant Provide and "Rock" Directionl Bore 2" SDR 11 Duct Part#:Carlon A13C6N1JNNE (2 inch) or equivelant Provide and "Cobble" Directionl Bore 2" SDR 11 Duct if encounterd (provide unit rate only) Part#:Carlon A13C6N1JNNE (2 inch) or equivelant Provide and Install Quazite (Strongwell)/Polymer Concrete (24x36X36) with extra heavy duty cover marked Fiber Optics. Quazite #PG2436BB36 Base / #PG2436HH21 (ANSI Tier 22) 1 Piece Cover (no substitut Provide and Install Quazite (Strongwell)/Polymer Concrete (30x48X36) with 2 piece extra heavy duty cover marked Fiber Optics. Quazite #PG3048BB36 Base / #PG3048HH21 (ANSI Tier 22) 2 Piece Cover (no s Provide and Install Flush Mount Locate Housing with cast iron housing and collar mfr. Handley Industries 2 inch Cathodic test station Part Number T2IC5F1LQ, or equivalent. Provide and Install Locate post 6 ft. high x 3 in. diameter locate post white base with orange removable tip cover. Each locate post will have a Diggers Hotline sticker with their 1-800-242-8511 on i Provide and Install Ground Rod 5 ft. x 1/2 in. copper clad ground rod. Non-manufacturer specific. 1800 pound mule tape Carlon TL38203 or approved equivalent manufacturer for both pulling initial cables and spare for future use. Locate Wire #12 AWG UL TYPE USE 2/RHH/RHW-2 outdoor rated polyethylene-jacketed, stranded copper. Non-manufacturer specific. Split Duct Plug 2 in. outside diameter split plugs with interior port diameter sufficient for cable size. Carlon or approved equivalent. Labor to Pull Fiber Optic Cable, Muletape, and Locate Wire Through New Exterior Duct Labor to Pull Fiber Optic Cable, Muletape, and Locate Wire Through Existing Exterior Duct Concrete Removal and Replace Hardsurface core, vacuum excavation, backfill, and epoxy core replacement per City Requirements (soil potholing incidental to directional boring costs) Pull Fiber Optic Cable and Muletape Through Existing Interior Duct Provide and Install Exterior 2 in. Galvanized Rigid Steel Piping with Couplers and bushings. *Exact Footage - Include Extra* Provide and Install Exterior 1/2 in. Galvanized Rigid Steel Piping with Couplers and bushings. Provide and Install Single Gang weatherproof outlet box with gasketed 2-screw blank steel cover Non-manufacturer specific. Provide and Install NEMA 3R Rated Pull Box 12inx12inx6in screw cover Grey NEMA 3R pull box. Hoffman A12R126 or approved equivalent. Outdoor fusion splicing. Including fusion Splice Sleeves Clear heat shrink fusion splice sleeve with steel reinforcing rod. Including consumeables Non-manufacturer specific. Indoor fusion splicing. Including fusion Splice Sleeves Clear heat shrink fusion splice sleeve with steel reinforcing rod. Including consumeables Non-manufacturer specific. OTDR Pre-Acceptance Test all fiber optic reel strands at 1310nm and 1550 nm (96 + 96 + 12) Bi-Directional OTDR and Power Meter and Light Source Testing at 1310nm and 1550nm for each strand. 8 Total Tests per Strand Provide 12 Strand Fiber Optic Cable - Allwave Singlemode - single jacket all dielectric. Part Number OFS AT3BE-12TT-012 or approved equivalent. Provide 96 Strand Fiber Optic Cable - Allwave Singlemode - single jacket all dielectric. Part Number OFS AT3BE-12TT-96 or approved equivalent. (On 2 Reels) 48 Port Rack Mount Patch & Splice Panel Loaded, 012 LC/UPC, 1RU, Loaded, Singlemode, Includes, Duplex Adapters, Blanks, Splice Trays, Pigtails, Black. Mfr: Total Cable Solutions Wall Mount Patch Panel, CORE Dual Door, 024 LS/UPC Capability, Loaded, with (1) 6 ct. Duplex LC/UPC Singlemode, Blanks, (1) 12 ct. Splice Trays, (1) 12 ct. Sub-Distribution Style Pigtail, Black. Mfr: FOSC 450 D6 Gel Case 768 Capacity. Part Number Commscope FOSC450-D6-6-NT-0-D-OV D Case - 72 Capacity OSP Splice Tray. Part Number Commscope FOSC-ACC-D-TRAY-72 Fiber Optic Cable Labels. Panduit #PST-FO. Provide and Directionl Bore 2 inch SDR 11 Duct Part#:Carlon A13C6N1JNNE (2 inch) or equivelant Provide and Install Quazite (Strongwell)/Polymer Concrete (24x36X36) with extra heavy duty cover marked Fiber Optics. Quazite #PG2436BB36 Base / #PG2436HH21 (ANSI Tier 22) 1 Piece Cover (no substitut Provide and Install Locate post 6 ft. high x 3 in. diameter locate post white base with orange removable tip cover. Each locate post will have a Diggers Hotline sticker with their 1-800-242-8511 on i Provide and Install Ground Rod 5 ft. x 1/2 in. copper clad ground rod. Non-manufacturer specific. 1800 pound mule tape Carlon TL38203 or approved equivalent manufacturer for both pulling initial cables and spare for future use. Locate Wire #12 AWG UL TYPE USE 2/RHH/RHW-2 outdoor rated polyethylene-jacketed, stranded copper. Non-manufacturer specific. Split Duct Plug 2 in. outside diameter split plugs with interior port diameter sufficient for cable size. Carlon or approved equivalent. Labor to Pull Fiber Optic Cable, Muletape, and Locate Wire Through New Exterior Duct Provide and Install Interior 2 in. EMT Piping with couplers and bushings. Non-manufacturer specific. Concrete Removal and Replace Hardsurface core, vacuum excavation, backfill, and epoxy core replacement per City Requirements (soil potholing incidental to directional boring costs) Pull Fiber Optic Cable and Muletape Through New Interior Duct Provide and Install Exterior 2 in. Galvanized Rigid Steel Piping with Couplers and bushings. *Exact Footage - Include Extra* Provide and Install Exterior 1/2 in. Galvanized Rigid Steel Piping with Couplers and bushings. Provide and Install Single Gang weatherproof outlet box with gasketed 2-screw blank steel cover Non-manufacturer specific. Provide and Install NEMA 3R Rated Pull Box 12inx12inx6in screw cover Grey NEMA 3R pull box. Hoffman A12R126 or approved equivalent. Provide and Install Interior Type I Pull Box - 12inx12inx6in (Hoffman p/n ASE12X12X6) w/ screw cover. Outdoor fusion splicing. Including fusion Splice Sleeves Clear heat shrink fusion splice sleeve with steel reinforcing rod. Including consumeables Non-manufacturer specific. Indoor fusion splicing. Including fusion Splice Sleeves Clear heat shrink fusion splice sleeve with steel reinforcing rod. Including consumeables Non-manufacturer specific. Bi-Directional OTDR and Power Meter and Light Source Testing at 1310nm and 1550nm for each strand. 8 Total Tests per Strand Provide 12 Strand Fiber Optic Cable - Allwave Singlemode - single jacket all dielectric. Part Number OFS AT3BE-12TT-012 or approved equivalent. 1U Rack Mount Patch & Splice Panel Loaded, 012 LC/UPC, 1RU, Loaded, Singlemode, Includes, Duplex Adapters, Blanks, Splice Trays, Pigtails, Black. Mfr: Total Cable Solutions Fiber Optic Cable Labels. Panduit #PST-FO. Provide and Directionl Bore 2 inch SDR 11 Duct Part#:Carlon A13C6N1JNNE (2 inch) or equivelant 1800 pound mule tape Carlon TL38203 or approved equivalent manufacturer for both pulling initial cables and spare for future use. Locate Wire #12 AWG UL TYPE USE 2/RHH/RHW-2 outdoor rated polyethylene-jacketed, stranded copper. Non-manufacturer specific. Split Duct Plug 2 in. outside diameter split plugs with interior port diameter sufficient for cable size. Carlon or approved equivalent. Labor to Pull Fiber Optic Cable, Muletape, and Locate Wire Through New Exterior Duct Provide and Install Interior 2 in. EMT Piping with couplers and bushings. Non-manufacturer specific. Pull Fiber Optic Cable and Muletape Through New Interior Duct Provide and Install Exterior 2 in. Galvanized Rigid Steel Piping with Couplers and bushings. *Exact Footage - Include Extra* Provide and Install Exterior 1/2 in. Galvanized Rigid Steel Piping with Couplers and bushings. Provide and Install Single Gang weatherproof outlet box with gasketed 2-screw blank steel cover Non-manufacturer specific. Provide and Install NEMA 3R Rated Pull Box 12inx12inx6in screw cover Grey NEMA 3R pull box. Hoffman A12R126 or approved equivalent. Provide and Install Interior Type I Pull Box - 12inx12inx6in (Hoffman p/n ASE12X12X6) w/ screw cover. Outdoor fusion splicing. Including fusion Splice Sleeves Clear heat shrink fusion splice sleeve with steel reinforcing rod. Including consumeables Non-manufacturer specific. Indoor fusion splicing. Including fusion Splice Sleeves Clear heat shrink fusion splice sleeve with steel reinforcing rod. Including consumeables Non-manufacturer specific. Bi-Directional OTDR and Power Meter and Light Source Testing at 1310nm and 1550nm for each strand. 8 Total Tests per Strand Provide 12 Strand Fiber Optic Cable - Allwave Singlemode - single jacket all dielectric. Part Number OFS AT3BE-12TT-012 or approved equivalent. 1U Rack Mount Patch & Splice Panel Loaded, 012 LC/UPC, 1RU, Loaded, Singlemode, Includes, Duplex Adapters, Blanks, Splice Trays, Pigtails, Black. Mfr: Total Cable Solutions Fiber Optic Cable Labels. Panduit #PST-FO. UofM L.F. L.F. L.F. L.F. EACH EACH EACH EACH EACH L.F. L.F. EACH L.F. L.F. S.F. EACH L.F. L.F. L.F. EACH EACH EACH EACH EACH EACH L.F. L.F. EACH EACH EACH EACH EACH L.F. EACH EACH EACH L.F. L.F. EACH L.F. L.F. S.F. EACH L.F. L.F. L.F. EACH EACH EACH EACH EACH EACH L.F. EACH EACH L.F. L.F. L.F. EACH L.F. L.F. L.F. L.F. L.F. EACH EACH EACH EACH EACH EACH L.F. EACH EACH Quantity 22834 550 500 500 10 5 10 5 16 24384 24384 28 24384 597 620 39 28 8 4 1 1 300 24 204 24 350 33000 1 1 3 8 35 862 1 1 1 862 862 3 862 223 20 1 223 20 16 1 1 2 12 12 12 1650 1 3 177 177 177 1 177 26 26 10 6 1 1 1 12 12 12 450 1 2 J&R Underground, LLC Unit Price 12.35 85 55 17 1130 1960 125 115 31.5 0.2 0.26 2.85 1.25 3 27.5 325 10 50 38.5 25.5 150 27 27 6 42.5 0.8 0.85 1000 1000 450 450 1.93 11.85 1130 115 31.5 0.2 0.26 2.85 1.25 27.5 25 325 1.25 41.8 38.5 25.5 150 45 30 30 8 0.4 1000 1.2 11.85 0.2 0.26 2.85 1.25 27.5 3 41.8 38.5 25.5 150 45 30 30 6 0.4 1000 1.2 Extension 508820.39 281999.9 46750 27500 8500 11300 9800 1250 575 504 4876.8 6339.84 79.8 30480 1791 17050 12675 280 400 154 25.5 150 8100 648 1224 1020 280 28050 1000 1000 1350 3600 67.55 24407.12 10214.7 1130 115 31.5 172.4 224.12 8.55 1077.5 6132.5 500 325 278.75 836 616 25.5 150 90 360 360 96 660 1000 3.6 6039.87 2097.45 35.4 46.02 2.85 221.25 715 78 418 231 25.5 150 45 360 360 72 180 1000 2.4 539267.38 Underground Systems, Inc. Unit Price 11.7 80 70 45 1500 2000 150 100 30 0.15 0.25 5 1.5 3 45 275 5 100 50 50 350 45 40 7 7 0.35 1 1000 1000 450 60 5 11.7 1500 150 50 0.15 0.25 5 1.5 40 45 275 5 80 20 50 350 350 45 45 10 0.35 100 5 11.7 0.15 0.25 5 2 60 5 80 20 50 350 350 45 45 10 0.35 1000 5 Extension 537746.9 267157.8 44000 35000 22500 15000 10000 1500 500 480 3657.6 6096 140 36576 1791 27900 10725 140 800 200 50 350 13500 960 1428 168 122.5 33000 1000 1000 1350 480 175 29560.7 10085.4 1500 150 50 129.3 215.5 15 1293 8920 900 275 1115 1600 320 50 350 700 540 540 120 577.5 100 15 8228.2 2070.9 26.55 44.25 5 354 1560 130 800 120 50 350 350 540 540 120 157.5 1000 10 575535.8 Holtger Bros., Inc. Unit Price 12.9 145.9 105.9 35.9 1544 2582.5 174.95 102.75 86.1 0.09 0.21 15 1.5 3 43.83 561.65 2 40 50 100 200 65 65 4 30 0.45 1.2 800 800 600 45 5 12.9 1544 102.75 86.1 0.09 0.21 15 3 75 43.83 561.65 2 40 50 100 200 250 65 65 30 0.45 872 5 12.9 0.09 0.21 15 1.5 75 2 40 50 100 200 250 65 65 30 0.45 872 5 Extension 640042.6 294558.6 80245 52950 17950 15440 12912.5 1749.5 513.75 1377.6 2194.56 5120.64 420 36576 1791 27174.6 21904.35 56 320 200 100 200 19500 1560 816 720 157.5 39600 800 800 1800 360 175 40301 11119.8 1544 102.75 86.1 77.58 181.02 45 2586 16725 876.6 561.65 446 800 800 100 200 500 780 780 360 742.5 872 15 8873.4 2283.3 15.93 37.17 15 265.5 1950 52 400 300 100 200 250 780 780 360 202.5 872 10 689217 Arvig Unit Price 18.23 151.23 151.23 37.23 1715.56 2035.94 275.31 215.13 45.06 0.07 0.23 30.06 1.75 3 42.08 203.5 5 28.03 22.68 48.38 383.75 53.84 68.84 8 45 0.27 0.8 685 685 778.06 86.11 5.47 21.23 1715.56 215.13 45.06 0.07 0.23 23.38 2 23.03 58.44 203.5 0 8.03 22.68 58.38 283.75 310.19 53.84 68.84 45 0.27 685 5.47 23.23 0.07 0.23 30.06 3 28.03 3 18.03 12.68 58.38 283.75 310.19 91.34 68.84 67.5 0.27 685 11.47 Extension 764683.57 416263.82 83176.5 75615 18615 17155.6 10179.7 2753.1 1075.65 720.96 1706.88 5608.32 841.68 42672 1791 26089.6 7936.5 140 224.24 90.72 48.38 383.75 16152 1652.16 1632 1080 94.5 26400 685 685 2334.18 688.88 191.45 33481.8 18300.26 1715.56 215.13 45.06 60.34 198.26 70.14 1724 5135.69 1168.8 203.5 0 160.6 362.88 58.38 283.75 620.38 646.08 826.08 540 445.5 685 16.41 10002.95 4111.71 12.39 40.71 30.06 531 728.78 78 180.3 76.08 58.38 283.75 310.19 1096.08 826.08 810 121.5 685 22.94 808168.32